Model Number |
SF-50N, SF-100N |
Features
Installation requires minimum space and is very easy. To remove the Sludge , open the rotor and take out the rubber bucket.
Structures
When the undiluted solution is injected into a hole (1), fine grains inside rotating rubber bucket (2) get collected and the clean solution flows through the nozzle (3) and gets excreted through an outlet (4). To remove the sludge , open the cover (5), and take out the rubber bucket in the rotator. Remove the sludge and insert the rubber bucket to its original position to operate.

Specification
|
Model
|
Process Capacity (l/min)
|
Sludge Volumn (liter)
|
RPM of bowl (rpm)
|
Motor (Kw)
|
Required space (mm)
|
Inlet height (mm)
|
Outlet height (mm)
|
Weight 9kgf)
|
|
50Hz
|
60Hz
|
|
SF-50N
|
50
|
7
|
2000
|
2400
|
1.5
|
380x650
|
519
|
364
|
80
|
|
SF-100N
|
100
|
15
|
2000
|
2400
|
2.2
|
500x800
|
504
|
329
|
160
|
|